Model |
N/A 4RC410 |
Phase |
N/A 1 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 51 ft³/min87 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 62 ft³/min105 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 120 in. H2O300 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 141 in. H2O350 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 153 in. H2O380 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 157 in. H2O390 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 1.5 hp1.1 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 1.7 hp1.3 kW |
Voltage at 50 Hertz (Hz) Frequency |
N/A 200 to 240 V |
Voltage at 60 Hertz (Hz) Frequency |
N/A 115 V230 V |
Current at 50 Hertz (Hz) Frequency |
N/A 10.1 A |
Current at 60 Hertz (Hz) Frequency |
N/A 10.3 A20.6 A |
Sound Level |
N/A 62 dB |
Weight |
N/A 57 lb26 kg |
Thread Diameter (P) |
N/A 0.55 in |
Dimension A |
N/A 13.62 in346 mm |
Dimension B |
N/A 16.26 in413 mm |
Dimension D |
N/A 12.40 in315 mm |
Dimension E |
N/A 13.78 in350 mm |
Dimension F |
N/A 10.24 in260 mm |
Dimension H |
N/A 4.92 in125 mm |
Dimension J |
N/A 7.68 in195 mm |
Dimension K |
N/A 5.12 in130 mm |
Dimension M |
N/A 2.60 in66 mm |
Dimension N |
N/A 1.50 in38 mm |
Dimension O |
N/A 5.63 in143 mm |
Dimension Y*Z |
N/A 1.25 in |
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |