Model |
N/A 4RC630 |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 100 ft³/min170 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 118 ft³/min200 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 293 in. H2O730 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 281 in. H2O700 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 418 in. H2O1040 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 418 in. H2O1040 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 10.1 hp7.5 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 11.5 hp8.6 kW |
Voltage (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 190 V |
Voltage (Δ) at 50 Hertz (Hz) Frequency |
N/A 380 V |
Voltage (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 230 V |
Voltage (Δ) at 60 Hertz (Hz) Frequency |
N/A 460 V |
Current (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 32.0 A |
Current (Δ) at 50 Hertz (Hz) Frequency |
N/A 16.0 A |
Current (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 27.8 A |
Current (Δ) at 60 Hertz (Hz) Frequency |
N/A 16.0 A |
Sound Level |
N/A 76 dB |
Weight |
N/A 188 lb86 kg |
Thread Diameter (P) |
N/A 1.25 in |
Thread Diameter (R) |
N/A 0.55 in |
Dimension A |
N/A 2.49 in63 mm |
Dimension B |
N/A 17.69 in449 mm |
Dimension C |
N/A 7.30 in185 mm |
Dimension D |
N/A 14.61 in371 mm |
Dimension E |
N/A 15.98 in406 mm |
Dimension H |
N/A 15.29 in388 mm |
Dimension J |
N/A 9.29 in236 mm |
Dimension J' |
N/A 6.73 in172 mm |
Dimension K |
N/A 5.98 in152 mm |
Dimension M |
N/A 13.31 in338 mm |
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |