Model |
N/A HRC 025 |
Phase |
N/A 1 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 30 ft³/min51 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 36 ft³/min61 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 36 in. H2O90 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 44 in. H2O110 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 40 in. H2O100 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 41 in. H2O102 mbar |
Motor Power |
N/A 0.3 hp0.2 kW |
Voltage at 50 Hertz (Hz) Frequency |
N/A 230 V |
Voltage at 60 Hertz (Hz) Frequency |
N/A 115 V230 V |
Current (Δ) at 60 Hertz (Hz) Frequency |
N/A 4.6 A |
Current at 50 Hertz (Hz) Frequency |
N/A 1.6 A |
Current at 60 Hertz (Hz) Frequency |
N/A 2.3 A |
Sound Level |
N/A 53 dB |
Weight |
N/A 24 lb11 kg |
Dimension A |
N/A 9.65 in245 mm |
Dimension B |
N/A 9.84 in250 mm |
Dimension D |
N/A M6 |
Dimension E |
N/A 9.65 in245 mm |
Dimension F |
N/A 2.36 in60 mm |
Dimension G |
N/A 5.59 in142 mm |
Dimension J |
N/A 5.12 in130 mm |
Dimension K |
N/A 5.12 in130 mm |
Dimension M |
N/A 1.25 in |
Dimension N |
N/A 2.52 in64 mm |
Dimension O |
N/A 0.10 in2.5 mm |
Dimension P |
N/A 1.57 in40 mm |
Dimension Q |
N/A 2.76 in70 mm |
Dimension R |
N/A 8.66 in220 mm |
Dimension S |
N/A 5.91 in150 mm |
Dimension t |
N/A 2.76 in70 mm |
Dimension u |
N/A 3.15 in80 mm |
Dimension V |
N/A 8.86 in225 mm |
Dimension W |
N/A 0.39 in10 mm |
Dimension X |
N/A 3.54 in90 mm |
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |