Model |
N/A HRC 1200 |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 618 ft³/min1050 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 736 ft³/min1250 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 112 in. H2O280 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 108 in. H2O270 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 108 in. H2O270 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 104 in. H2O260 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 16.8 hp12.5 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 19.4 hp14.5 kW |
Voltage (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 190 V |
Voltage (Δ) at 50 Hertz (Hz) Frequency |
N/A 380 V |
Voltage (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 230 V |
Voltage (Δ) at 60 Hertz (Hz) Frequency |
N/A 460 V |
Current (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 56.0 A |
Current (Δ) at 50 Hertz (Hz) Frequency |
N/A 28.0 A |
Current (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 50.1 A |
Current (Δ) at 60 Hertz (Hz) Frequency |
N/A 29.0 A |
Sound Level at 50 Hertz (Hz) Frequency |
N/A 74 dB |
Sound Level at 60 Hertz (Hz) Frequency |
N/A 79 dB |
Weight |
N/A 256 lb116 kg |
Dimension A |
N/A 21.65 in550 mm |
Dimension B |
N/A 24.33 in618 mm |
Dimension D |
N/A M12 |
Dimension E |
N/A 25.43 in646 mm |
Dimension F |
N/A 6.10 in155 mm |
Dimension G |
N/A 11.46 in291 mm |
Dimension J |
N/A 7.76 in197 mm |
Dimension K |
N/A 11.77 in299 mm |
Dimension M |
N/A 4.00 in |
Dimension N |
N/A 5.91 in150 mm |
Dimension O |
N/A 8.15 in207 mm |
Dimension P |
N/A 16.30 in414 mm |
Dimension Q |
N/A 3.62 in92 mm |
Dimension R |
N/A 14.17 in360 mm |
Dimension S |
N/A 3.46 in88 mm |
Dimension t |
N/A 21.06 in535 mm |
Dimension u |
N/A 22.72 in577 mm |
Dimension V |
N/A 25.43 in646 mm |
Dimension W |
N/A 0.59 in15 mm |
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |