Model |
N/A HRC 1502 |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 653 ft³/min1110 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 771 ft³/min1310 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 177 in. H2O440 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 177 in. H2O440 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 237 in. H2O590 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 217 in. H2O540 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 33.5 hp25.0 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 38.9 hp29.0 kW |
Voltage (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 190 V |
Voltage (Δ) at 50 Hertz (Hz) Frequency |
N/A 380 V |
Voltage (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 230 V |
Voltage (Δ) at 60 Hertz (Hz) Frequency |
N/A 460 V |
Current (Δ)(Δ) at 50 Hertz (Hz) Frequency |
N/A 104.0 A |
Current (Δ) at 50 Hertz (Hz) Frequency |
N/A 52.0 A |
Current (Δ)(Δ) at 60 Hertz (Hz) Frequency |
N/A 90.2 A |
Current (Δ) at 60 Hertz (Hz) Frequency |
N/A 52.0 A |
Sound Level at 50 Hertz (Hz) Frequency |
N/A 74 dB |
Sound Level at 60 Hertz (Hz) Frequency |
N/A 78 dB |
Weight |
N/A 465 lb211 kg |
Thread Diameter (P) |
N/A 4.00 in |
Thread Diameter (R) |
N/A 4.00 in |
Thread Diameter (X) |
N/A M12 in |
Dimension A |
N/A 32.56 in826 mm |
Dimension B |
N/A 25.94 in658 mm |
Dimension C |
N/A 28.75 in731 mm |
Dimension E |
N/A 14.19 in360 mm |
Dimension F |
N/A 7.81 in198 mm |
Dimension G |
N/A 10.13 in257 mm |
Dimension H |
N/A 5.13 in131 mm |
Dimension K |
N/A 3.13 in79 mm |
Dimension t |
N/A 30.13 in765 mm |
Dimension u |
N/A 21.06 in535 mm |
Dimension Y |
N/A 7.06 in180 mm |
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |