Model |
N/A HRC 402 |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 88 ft³/min150 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 106 ft³/min180 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 132 in. H2O330 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 141 in. H2O350 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 169 in. H2O420 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 177 in. H2O440 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 3.0 hp2.2 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 3.4 hp2.6 kW |
Voltage (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency |
N/A 190 V |
Voltage (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency |
N/A 380 V |
Voltage (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency |
N/A 230 V |
Voltage (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency |
N/A 460 V |
Current (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency |
N/A 11.2 A |
Current (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency |
N/A 5.6 A |
Current (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency |
N/A 10.3 A |
Current (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency |
N/A 6.0 A |
Sound Level at 50 Hertz (Hz) Frequency |
N/A 66 dB |
Sound Level at 60 Hertz (Hz) Frequency |
N/A 69 dB |
Weight |
N/A 60 lb27 kg |
Dimension A |
N/A 12.48 in317 mm |
Dimension B |
N/A 12.40 in315 mm |
Dimension D |
N/A M6 |
Dimension E |
N/A 15.79 in401 mm |
Dimension F |
N/A 6.22 in158 mm |
Dimension G |
N/A 7.52 in191 mm |
Dimension J |
N/A 5.04 in128 mm |
Dimension K |
N/A 6.06 in154 mm |
Dimension M |
N/A 1.50 in |
Dimension N |
N/A 2.83 in72 mm |
Dimension O |
N/A 0.12 in3 mm |
Dimension P |
N/A 1.81 in46 mm |
Dimension Q |
N/A 18.98 in482 mm |
Dimension R |
N/A 6.02 in153 mm |
Dimension S |
N/A 10.04 in255 mm |
Dimension t |
N/A 8.86 in225 mm |
Dimension u |
N/A 12.44 in316 mm |
Dimension V |
N/A 5.91 in150 mm |
Dimension W |
N/A 3.74 in95 mm |
Dimension X |
N/A 5.35 in136 mm |
Dimension Y |
N/A 0.47 in12 mm |
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |