Model |
N/A HRC 752 |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Air Flow at 50 Hertz (Hz) Frequency |
N/A 188 ft³/min320 m³/h |
Air Flow at 60 Hertz (Hz) Frequency |
N/A 227 ft³/min385 m³/h |
Rated Vacuum at 50 Hertz (Hz) Frequency |
N/A 112 in. H2O280 mbar |
Rated Vacuum at 60 Hertz (Hz) Frequency |
N/A 92 in. H2O230 mbar |
Rated Pressure at 50 Hertz (Hz) Frequency |
N/A 104 in. H2O260 mbar |
Rated Pressure at 60 Hertz (Hz) Frequency |
N/A 80 in. H2O200 mbar |
Motor Power at 50 Hertz (Hz) Frequency |
N/A 4.0 hp3.0 kW |
Motor Power at 60 Hertz (Hz) Frequency |
N/A 4.6 hp3.4 kW |
Voltage (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency |
N/A 190 V |
Voltage (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency |
N/A 380 V |
Voltage (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency |
N/A 230 V |
Voltage (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency |
N/A 460 V |
Current (Double Wye connection (YY)) at 50 Hertz (Hz) Frequency |
N/A 12.5 A |
Current (Wye (Star) Connection (Y)) at 50 Hertz (Hz) Frequency |
N/A 7.2 A |
Current (Double Wye connection (YY)) at 60 Hertz (Hz) Frequency |
N/A 12.6 A |
Current (Wye (Star) Connection (Y)) at 60 Hertz (Hz) Frequency |
N/A 7.3 A |
Sound Level at 50 Hertz (Hz) Frequency |
N/A 73 dB |
Sound Level at 60 Hertz (Hz) Frequency |
N/A 76 dB |
Weight |
N/A 108 lb49 kg |
Dimension A |
N/A 22.06 in560 mm |
Dimension B |
N/A 19.00 in483 mm |
Dimension C |
N/A 19.06 in484 mm |
Dimension D |
N/A 16.06 in408 mm |
Dimension E |
N/A 8.19 in208 mm |
Dimension F |
N/A 4.69 in119 mm |
Dimension G |
N/A 8.75 in223 mm |
Dimension H |
N/A 7.44 in113 mm |
Dimension J |
N/A 2.56 in65 mm |
Certification |
N/A Canadian Underwriters Laboratories (cUL) European Conformity (CE) International Efficiency Class 3 - CC339B (IE3) Underwriters Laboratories Recognized Component for Canada (c) and United States (us)) - E493872 |
|
N/A All Republic Regenerative Blowers are available in pre-assembled kits for either pressure or vacuum applications. These kits include an inlet filter, gauge and relief valve, and are factory tested prior to shipment. Optional items for these kits include check valve, and tube adaptor; washdown motors, explosion proof motors, or other specialty motors; noise enclosures; and control panels such as VFD's, PLC's, or starter panels. |
|
N/A The performance curves are based on air at a temperature of 59 ºF and an atmospheric pressure of 29.91 inch Hg with a tolerance of ±10%. The total pressure differences are valid for inlet and ambient temperatures up to 77 ºF. Suction capacity relates to inlet conditions. Pressure capacity relates to atmospheric conditions. For other conditions please contact Republic. Three phase motor tolerances are ±10% for fixed voltage motors and ±5% for voltage range motors. Single phase machines are designed with a ±5% tolerance. The frequency tolerance is ±2% maximum. |